Inches of water, wc, inch water column (inch WC), inAq, Aq, or in is a non-SI unit for pressure. The units are by convention and due to the historical measurement of certain pressure differentials. It is used for measuring small pressure differences across an orifice, or in a pipeline or shaft.〔(Inches of something - Link broken as of 4-8-2014. The UK NPL FAQ pages have issues http://www.npl.co.uk/science-technology/mass-and-force/faqs/ )〕 Inches of water can be converted to a pressure unit using the formula for pressure head. An ''inch of water column'' (iwc) is synonymous with an ''inch of water gauge'' (iwg). It is defined as the pressure exerted by a column of water of 1 inch in height at defined conditions. For example, 39 °F (4 °C) at the standard acceleration of gravity; 1 inAq is approximately equal to 249 pascals at 0 °C. Alternative standard conditions in uncommon usage are 60 °F, or 68 °F (20 °C), and depends on industry standards rather than on international standards. In North America, air and other industrial gasses are often measured in inches of water when at low pressure. This is in contrast to inches of mercury or psi for larger pressures. One usage is in the measurement of air ("wind") that supplies a pipe organ and is referred simply as ''inches''. It is also used in natural gas distribution for measuring utilization pressure (''U.P.'', i.e. the residential point of use) which is typically between 6 and 7 inches WC (6~7" WC) or about 0.25 psi. 1 inAq ≈ .036 psi, or 27.7 inAq ≈ 1 psi. : ==See also== *Barometer *Centimetre of water *Pressure head 抄文引用元・出典: フリー百科事典『 ウィキペディア(Wikipedia)』 ■ウィキペディアで「Inch of water」の詳細全文を読む スポンサード リンク
|